Baseline accuracy estimator
Base se doori badhne par RTK accuracy ghatti hai. Slider ghumao aur apne baseline ke liye expected horizontal/vertical dekho — spec-based estimate hai.
| Baseline | Expected H | Expected V | Note |
|---|---|---|---|
| 0–10 km | 8 mm + 1 ppm | 15 mm + 1 ppm | Best. VRS ideal. |
| 10–20 km | 10 mm + 1 ppm | 20 mm + 1 ppm | Good for stakeout. |
| 20–35 km | 12 mm + 1.5 ppm | 25 mm + 1.5 ppm | VRS limit zone — check FIXED. |
| 35–50 km | 20 mm + 2 ppm | 40 mm + 2 ppm | Degraded — prefer BHR-NEAR, longer occupation. |
| >50 km | Not recommended for RTK | Use static/PPK | Move closer or use static. |
Your baseline 12 km → 10–20 km: H 10 mm + 1 ppm, V 20 mm + 1 ppm
Scintillation warning: 19:00–01:00 IST (equinox peak) me accuracy degrade ho sakti hai chahe baseline chhoti ho. Critical stakeout daylight me karo. Spec-based estimate — site conditions apply.
Disclaimer: spec-based estimate; multipath, sky view aur scintillation se actuals badal sakte hain. Critical work se pehle known point check karo.